Home - AFL Uniforms - Torque Transducer – New Information On The Subject..

Torque Transducer – New Information On The Subject..

Posted on October 6, 2019 in AFL Uniforms

The complete point of having Torque Measurement is to be able to weigh your loads sufficiently and accurately, so when they are not giving us the accuracy that we expect, it leaves us wondering just what could be affecting the accuracy of our equipment. Well, there are a number of reasons as to why your load cell & torque sensors are not offering the high level of accuracy that you would expect, with each of them being listed here.

The Precision from the Load Cell & Torque Sensors – First thing you need to be doing when you find yourself chasing accurate weighing accuracy is always to decide on a top quality load cell & torque sensors manufacturer. While all manufacturers will proclaim that their products offer high levels of accuracy, only the top brands will often be able to provide the best accuracy.

A good load cell as well as its torque sensors will usually have good response times (how rapidly they provide an accurate reading), is not going to react to much to temperature alterations in the environment, will not suffer with creep (a change in the reading after 2-3 minutes of being stationary), and definately will have very low ‘nonrepeatability’ (variations in the readings for the very same load after repeated loadings).

Factors using the Load – The precision of a load cell & indicator reading could be impacted by how the load is put on the weighing system. To make certain an accurate reading, the stress has to be placed on each cell properly so that as specified from the manufacturer.

If a load has been applied poorly, such as the load being twisted, the cell and weighing system will simply throw up inaccurate results. To ensure complete accuracy when weighing, the stress must be placed in such a way which can be supporting each of the weight proportionally.

Outside Forces – Another reason as to why accuracy might be affected on Button Load Cell will be the many outside forces that could be slightly altering the body weight force. Wind, shock loading, vibration, and modifications in temperature can all provide an effect on the true accuracy of the reading.

A cross-wind might have an effect that the load feels lighter than it actually is while shock is the procedure of putting on more load weight than what the weight capacity of the cells are. Vibrations from other nearby machines may also omqzxd fluctuations in a weight whilst temperature modifications in environmental surroundings could cause materials within the load to either expand or contract.

Signal Interference – The final manner in which the precision of the weight of the load may be affected is through interference with all the signal transmission. The stress cell electrical signal can be suffer from interference from radio frequencies, electromechanical interference, and even moisture in the air may cause interference for the electrical signal.

Summary – So to make sure that 3 Axis Load Cell are as accurate as possible; you should be knowledgeable of just what could affect that accuracy and place measures set up to prevent those occurrences from happening. Just use the best manufacturers of load cells & torque sensors leading brands, load them correctly, make certain that outside forces are restricted, and this there is very little chance of signal interference.